Features & Options
The new development with more comfort Inclined parking
on upper and lower level. Space-saving parking with
comfort restrictions
* Scope
of supply
* Options
Features of the Kipparker N 3000 comfort E/D
* Key switch incl. emergency stop, dead man's control
type with brief operating instructions and wiring to
aggregate
* "lockable key switch" key is extractable
from switch only when the installation is lifted
* E/D-installation
with 2 platforms, 2 columns, 2 hydraulic cylinders,
additional initial hub and hydraulic block
* Width
of lot 230cm and depth of pit 155/140 cm as standard
* Width
of lot modified to 240cm and wider for more car <ETH>
comfort, station wagons HT (height on top) 150 only
possible, if CL 305 instead of CL 290
* Synchronizing
device to improve operation with unequal load distribution
* Entering
wedge for car positioning
* Safety
device to prevent from lowering in case of pipe fracture
* Mounting
on installation and aggregate with HD-anchors, wiring
with impact dowels
* Bonded
anchors for increased foundation requirements
* Drive
unit "Silencio" with tubing and wiring to
the installation
* Hydraulic
package "parallel operation": simultaneous
lifting of 2 or more installations per aggregate at
given pump capacity, or simultaneous lowering respectively
* Structure-borne noise package to comply with DIN 4109
and adherence to sound insulation measure Rw 55
* Sound insulation hood to minimize airborne sound
* HVLP-oil for excessive fluctuations in temperature
* Drive
plates in trapezoid style sheeting
* Rubber profiles in the pedestrian area, width 40cm
or 60cm, in the pedestrian and drive area 60cm and 40cm
* Corrosive
prevention "Classic" of drive plates by continuous
line-galvanizing to DIN EN 10142/10143
** Corrosion
prevention "Premium" of drive plates by individual
piece-galvanizing to DIN ISO 1461
* Corrosion prevention "Classic Plus" of drive
plates by line-galvanizing to DIN EN 10142/10143 and
coating of the top surfaces (dependent on the market
needs the scope of supply contains cinched and powder
coated sheet metal)
* Corrosion prevention "Premium Plus" of the
driving plates by individual piece-galvanizing to DIN
ISO 1461 and coating of the top surfaces
* Railings
to avoid risk of falling onto the platform, insofar
as necessary (Note: Safe guarding against shearing and
squeezing have priority and must be provided by the
proprietor)
* Ramps
when door facing is not available to install the door
slide rail, pit length must be 525cm, at the minimum
* Vehicle
load: 2,0 to, length: 5m, as per "vehicle data"
* A maintenance contract is recommended
* Attendance and cleaning to requirements or at regular
intervals is recommended
Intersections/Customer's Duties
• Lockable main switch, near to aggregate, completed
at the beginning of erection
• Capacity of the aggregate: 400volt, 50hz, threephrase
motor, 3,0kw
• Supply line to main switch 5 x 1,5mm2 or to
local regulations, fuse protection 3 x 16 amp, slow
fuse
• Electrical potential equalisation (foundation
grounding steel-construction to VDE 0100 T410)
• Level surface (L x W) 50cm x 20cm to attach
the control unit, adjacent to the installation, outside
the operational platform area
• Safeguarding to DIN EN 294 Lighting to DIN 67528,
illumination of parking lots and buildings for parking
• Foundation exactly to size, clean and dry
• Compliance with installation requirements as
per quotation
• The measurements are minimum. Tolerances to
VOB part C (DIN 18330, 18331) should be considered supplementary
|