Features & Options
* Scope of supply
* Options
Features of the Uniparker 5003
*
Control element incl. emergency stop in automatic-control
with brief operating instructions and wiring to switch
cabinet.
* Installation with
sliding platforms and one empty space on the entrance
level and with movable platforms on the level above
and below.
* Width of lot 230cm
and depth of pit 175 cm and inside height 345cm as standard
* Width of lot modified 240cm and wider or version
depth of pit 200 recommended for higher conveniences
* Mono-hub cylinder
to drive the horizontal movable platforms with looped-around
suspension elements, sliding platforms with electrical
drive
* entering wedge
for car positioning.
* Safety device to
prevent kneeling by leakage, pipe burst, fracture of
suspension elements.
*
Mounting of installation and aggregate with HD-anchors,
electrical wiring with impact dowels
* Bounded anchors for increased foundation requirements
*
Drive unit "Silencio" with tubing and wiring
to the installation
* Structure-borne noise package to comply with
DIN 4109 and adherence to sound insulation measure Rw
Ô55
* Sound insulation hood to minimize airborne
sound
* HVLP-oil for excessive fluctuations in temperature
*
Drive plates in trapezoid style sheeting
* Rubber profiles in the pedestrian area, width
40cm or 60cm, in pedestrian and drive area 60cm and
40cm
* Luxury sheet metal
*
Corrosion prevention "Classic" of drive plates
by continuous line-galvanizing to DIN EN 10142/10143
* Corrosion prevention "Premium" of
drive plates by individual piece-galvanizing to DIN
ISO 1461
** Corrosion
prevention "Classic Plus" of drive plates
by line-galvanizing to DIN EN 10142/10143 and coating
of the top surfaces (dependent on the market needs the
scope of supply contains zinc and powder coated sheet
metal)
* Corrosion prevention "Premium Plus"
of drive plates by individual piece-galvanizing to DIN
ISO 1461 and coating of the top surfaces
*
Sliding doors for fall-danger prevention into the pit
and railings from the platform (Notice: safe guarding
against shearing and squeezing have priority and must
provided by the proprietor sideways and behind the installation)
* Remote control and/or automatic-drive for sliding
doors
* Modem for teleservice for online-analysis and
help
* Assembly of the ramp behind the columns, length
of pit must have at least 560cm
* Vehicle load 2,0
to 5m length according to vehicle data
* Extra capacity of sliding platforms to 2,5
to, vehicle length to 5,10m, pit length plus 10 cm
A maintenance contract is recommended
Intersections/ Customer's duties
Aggregate power: 400V, 50Hz, three-phase motor
3,0Kw, assembly in pit range or in direct near of the
system, LBH ca 60 x 22 x 40 cm
Supply line to switch cabinet 5x 1,5mm2, or to
local regulations, fuse protection 3 x 16amp, slow fuse
Electrical potential equalisation (foundation
ground steel-construction to VDE 0100 T410)
Telephone line dto by option modem and teleservice,
after consolations
Free space for switch cabinet LBH ca 60 x 22
x 80cm, with swing door in immediate near to installation
(max 6m) with access to the parking system
Level surface HxB 50cm x 20cm to attach the control
unit in direct near of the installation
Safeguarding to DIN EN 294
Lighting to DIN 67528, illumination of parking
lots and buildings for parking
Foundation exactly to size, clean and dry Compliance
with installation requirements as per quotation
The measurements are minimum finished dimensions.
Tolerances to VOB part C (DIN 18330, 18331) should be
considered supplementary. Measurements in cm.
Technical alterations reserved, alterations in the scope
of supply reserved. Version 15/2004 |